High rate scan mode with external trigger – Sony XCL-U1000 User Manual

Page 15

Advertising
background image

15

Functions of the XCL-U1000C/U1000

TRG

LVAL

DVAL

Output

Vertical timing

(Horizontal timing is the same as Normal mode.)

FVAL

T1

T2

T3

1H

b

a

2

1

1600CL

320CL

d

c

Trigger mode

T1

*1

T2

Shutter

*2

T3 [ms]

1/30 s

37.40

1/100 s

14.04

1/120 s

12.40

See the

1/250 s

8.08

Edge detection

formula on

100 us or more,

1/500 s

6.06

the right.

1 s less than

1/1000 s

5.08

1/2000 s

4.53

1/5000 s

4.28

1/10000 s

4.17

66.7 ms

70.82

33.3 ms

37.34

See the

100 us or

10.0 ms

14.02

Puls width

formula on

more,

8.33 ms

OFF

12.33

detection

the right.

1 s less than

4 ms

8.03

1 ms

6.03

100 us

4.13

*1 Set a trigger cycle (1/T1) using the following

formula.

T1>1920 (a+b)/36000+0.1[ms]

Refer to the table of the high rate scan mode (no
external trigger) for the values of “a,” “b,” “c,” and
“d.”

*2 In the edge detection mode, you cannot set a shutter

speed slower than 1/15 s. If the rate is over 30 fps,
you cannot set a shutter speed to 1/30 s. Set a rate
referring to the table of the high rate scan mode (no
external trigger).

High rate scan Mode with external trigger