Camera Control Command

■ γ Table Data Setting

[Command]

GTBL

[Parameter1] <Data setting start point (0 to 1,023)>

[Process]

Enters

γ table data setting mode that

allows users to input data to the table. To
exit the mode, input “Q.”

Binning/Partial Setting Commands

■ Binning Mode Setting (For XCL-U1000 only)

[Command]

BINNING

[Parameter1] <Mode (0 to 1)>

0: OFF

t Binning OFF

1: V

t Vertical binning

[Process]

Selects a binning mode.

■ Partial Scan Setting

[Command]

PARTIAL

[Parameter1] <Mode (0 to 1)>

0: OFF
1: ON

[Parameter2] <Readout start position (0 to 15)>
[Parameter3] <Readout end position (1 to 16)>

[Process]

Selects a partial scan mode using
Parameter1, specify readout area of
partial scan using Parameter2 and 3. If
no value is set for a parameter, the
currently set value for the parameter
becomes valid.
The effective partial scan range is shown
below. If an input value is out of range,
it becomes invalid.

(Readout start position) < (Readout
end position)
{(Readout end position) – (Readout
start position)} < 16

IN/OUT Setting Commands

■ External Trigger Signal Input Selection

[Command]

EXTTRG

[Parameter1] <Specified input (0 to 1)>

0: Camera Link

t Inputs signals via a Camera Link

connector.

1: DC

t Inputs signals via a DC connector.

[Process]

Selects an input path for external trigger
signals.

■ Internal Color Bar Output Setting (For XCL-

U1000C only)

[Command]

COLORBAR

[Parameter1] <Mode (0 to 1)>

0: OFF
1: ON

[Process]

Selects whether to output the internal
color bar.

■ Internal Gray Scale Output Setting (For XCL-

U1000 only)
[Command]

GRAYSCALE

[Parameter1] <Mode (0 to 1)>

0: OFF
1: ON

[Process]

Selects whether to output the internal
gray scale.

■ Serial Communication Speed Setting

[Command]

BRATE

[Parameter1] <Baud rate setting (0 to 4)>

0: 4800 [bps]
1: 9600 [bps]
2: 19200 [bps]
3: 38400 [bps]
4: 57600 [bps]

[Process]

Selects a serial communication speed.