Command specifications, Camera control commands – Sony XCL-U1000 User Manual

Page 17

Advertising
background image

17

Camera Control Command

• When no parameter is input for a command with

parameters, the screen displays the current parameters
of the command.

<Input>

PARTIAL 1 0 15 <CR>

<Output on screen> OK <CR>
<Input>

PARTIAL <CR>

<Output on screen> 1,0,15 <CR>

• If an input value is out of parameter range, the

command is invalid and the screen displays “ERROR
SYNTAX.”

<Input>

PARTIAL 1 0 20 <CR>

<Output on screen> ERROR SYNTAX <CR>

• If an invalid command name is input, the screen

displays “ERROR SYNTAX”.

<Input>

PART 1 0 20 <CR>

<Output on screen> ERROR SYNTAX <CR>

• If the Enter key is pressed with no command input,

only the carriage return is carried out.

Command
Specifications

This section describes the details of control commands
available for the XCL-U1000C/U1000, classified by
category.

Camera Control Commands

Camera control commands fall into eight categories.

Category

Description

AFE

Sets AFE modes.

Shutter/Trigger

Selects a shutter speed and a trigger mode.

WB

Adjusts white balance.

DTL

Adjusts edge enhancement.

Color

Adjusts color matrix.

Gamma

Sets

γ table.

Binning/Partial

Selects a binning mode and a partial scan mode.

IN/OUT

Sets input/output of a camera.

All the parameters used in camera control commands
are saved in a Flash ROM fitted with a microcomputer.

AFE Setting Commands

■ Gain-Step Setting

[Command]

GAIN-STEP

[Parameter1] <Gain (0 to 18)> [dB]

[Process]

Sets VGA gain value of AFE IC. The
value set in “0 dB gain auto adjustment”
is applied to “0 to 18 dB.”

■ Gain-Fine Adjustment Setting

[Command]

GAIN-FINE

[Parameter1] <Gain (0 to 522)>

[Process]

Devides “Gain-Step Setting” range (0 to
18 dB) into 522 portions and fine-tunes
VGA gain value of AFE IC.

■ Pedestal Setting

[Command]

PEDESTAL

[Parameter1] <Pedestal level (0 to 255)>

[Process]

XCL-U1000: Sets AFE clamp level.
XCL-U1000C: Sets DSP offset level.

Advertising