1 specifying delay time for i·c, 1 specifying delay time for i²c, Table 19.2 – Siemens TC63 User Manual

Page 451: Values for calculating the delay, Figure 19.1, Formula for calculating the delay, Delayone, Delaytwo, Tc63 at command set

Advertising
background image

TC63 AT Command Set

19.7 AT^SSPI

s

TC63_ATC_V00.490

Page 451 of 501

5/24/05

Confidential / Draft - Do not copy

I²C: This parameter specifies a delay after a write frame. See Section

19.7.1

,

Specifying Delay Time for I²C

for

further details.
[0]

(&F)

...FFFF

(Unsigned 16 bit value)

I²C: This parameter specifies the delay after a read frame. See Section

19.7.1

,

Specifying Delay Time for I²C

for

further details.
[0]

(&F)

...FFFF

(Unsigned 16 bit value)

19.7.1 Specifying Delay Time for I²C

The following figures are provided to assist you in specifying appropriate values for the parameters

<delayOne>

and

<delayTwo>

. All delays are relative to the data transfer rate. To calculate the delay use the formula and the

values given below.

Table 19.2: Values for calculating the delay

Subparameter

Bit

Hexadecimal

Selected function

Interface type

D15 - D12

0

I²C bus (default)

Port

D11 - D8

0

Internal port

Data transfer rate

D7 - D4

0

1

I²C at 100 kbps

I²C at 400 kbps (default)

Protocol

D3 - D0

0

ASCII (hex coding)

<delayOne>

(num)

<delayTwo>

(num)

Figure 19.1: Formula for calculating the delay

Parameter

Values

Delay value

Value set with parameter

<delayOne>

or

<delayTwo>

Master clock

13 MHz

Default data transfer rate

400 bps

User data transfer rate

Value selected with subparameter data transfer rate within

<basicConfigura-

tion>

, for example 100 kbps or 400 kbps

Delay_min for Write

7.4 µs at 100 kbps

2.0 µs at 400 kbps

Delay_min for Read

9.9 µs at 100 kbps

2.6 µs at 400 kbps

Advertising