Specifying Alarm Output

For accessing the MAIN MENU, see page 13 – 14.

If you have connected an external beeper or indicator to the alarm output terminal (ALARM OUT) on the rear
panel, specify the following settings. You can also obtain a notification on the screen while an alarm occurs.
(For connecting alarm devices, see page 10.)

1

1

1

1

Select “POLARITY” and specify a polarity for the
signal.

NO : Normal Open (Closes when alarm input is detected).

NC : Normal Close (Opens when alarm input is detected).

2

2

2

2

Select “ALARM TIME” and specify duration time
to output alarm.

• Select from: 5S, 10S, 15S, 20S, 30S, 1M, 2M, 3M, 4M or 5M

(S = second, M = minute)

3

3

3

3

Set “MENU” to “END” and press the SET button.

R

Finishes the settings screen and returns to the normal
monitoring screen.

• If you want to return to the previous screen, select “BACK” and

press the SET button.

ALARM OUT SETTING (Alarm output)

ALARM

OUT

ON

SET

ALARM

(SET)

SET

MAIN MENU

LANGUAGE

SET

TITLE

OFF

SYNC

INT

EXPOSURE

SET

DAY/NIGHT

AUTO

WHITE BALANCE

ATW

OPTION

SET

PRESET

OFF

MENU

END

ALARM

SET

ALARM SETTING

ALARM SIGN

OFF

PRESET

OFF

MENU

BACK

ALARM IN

SET

ALARM OUT

ON

MEMO: For the electrical characteristics of alarm output, the

nominal output of the open collector (grounded emitter) is
18 V 25 mA.

ALARM OUT SETTING

ALARM TIME

5S

POLARITY

NO

MEMO: You can display alarm on the monitor screen.

(See page 45)