Sony Ericsson GR64 User Manual

Page 63

Advertising
background image

LZT 123 1834

63


Signal

Mode

Value

Minimum input voltage

2.5

V

Active High

Maximum input voltage

12.0

V

SERVICE

Inactive Low

Maximum input voltage

0.8

V

There are two methods for updating the firmware in the GR64:
Sony Ericsson Emma III and Updater. The Emma III system is a web
based tool that accesses a Sony Ericsson server from which signed
software can be downloaded. The Updater is a local application
that downloads a signed image provided by SEMC.

5.13 Buzzer

Pin

Name

Direction

Function

31 BUZZER

Output Buzzer

Output

Connecting the BUZZER signal to an inverting transistor-buffer followed by a
piezoelectric transducer enables the wireless modem to play pre-programmed
melodies or sounds.

5.14 LED

Pin

Name

Direction

Function

33 LED

Output LED

control

signal

The LED interface is intended to operate a status LED, which can be programmed on
and off, or for a particular blink sequence. The LED signal is derived from a standard
GPIO and does not have sufficient drive capability to operate an LED directly, so it
requires the user to implement some form of transistor circuit. A recommended
implementation is shown below.

NOTE

Advertising