10.5 Environmental Specification
Test Case
Test Summary
Ref Standard
Heat Test
Temp: max storage 
Humidity: nominal 
Duration: 16 hours 
IEC 60068-2-2
Cold Test
Temp: min storage 
Duration: 16 hours 
IEC 60068-2-1
Temperature Cycling
Temp (low) : min storage 
Temp (high) : max storage 
2 hrs dwell at each extreme 
6 hrs transition between temps 
Duration: 5 cycles x 16 hours 
 (80 hrs total) 
IEC 60068-2-14
Thermal Shock Test
Temp (low) : min storage 
Temp (high) : max storage 
6 min dwell at each extreme 
0.5 to 3 min transition 
Duration: 30 cycles (Group 2,3) 
IEC 60068-2-14
Moist Heat Cyclic Test
Temp (low) : nominal ambient 
Temp (high) : max operating 
Humidity (high) : 95% ±5% RH 
Humidity (low) : 93% ±5% RH 
9 hr dwell at each temperature 
3 hr transition between temps 
Duration: 6 cycles x 24 hours 
 (144 hrs total) 
IEC 60068-2-30
Operational Durability
SIM insertion : 500 cycles 
System connector : 10,000 cycles 
Flips/Hinges : 1,000 cycles 
RF connector : 5,000 
1/52 41-FEA 202 8370
Free Fall Test
1m drop height on to concrete 
 - all sides 
 - all faces 
 - all corners 
 - any extended features 
IEC 60068-2-32 Test Ed