10.5 Environmental Specification

Test Case

Test Summary

Ref Standard

Heat Test

Temp: max storage
Humidity: nominal
Duration: 16 hours

IEC 60068-2-2

Cold Test

Temp: min storage
Duration: 16 hours

IEC 60068-2-1

Temperature Cycling

Temp (low) : min storage
Temp (high) : max storage
2 hrs dwell at each extreme
6 hrs transition between temps
Duration: 5 cycles x 16 hours
(80 hrs total)

IEC 60068-2-14

Thermal Shock Test

Temp (low) : min storage
Temp (high) : max storage
6 min dwell at each extreme
0.5 to 3 min transition
Duration: 30 cycles (Group 2,3)

IEC 60068-2-14

Moist Heat Cyclic Test

Temp (low) : nominal ambient
Temp (high) : max operating
Humidity (high) : 95% ±5% RH
Humidity (low) : 93% ±5% RH
9 hr dwell at each temperature
3 hr transition between temps
Duration: 6 cycles x 24 hours
(144 hrs total)

IEC 60068-2-30

Operational Durability

SIM insertion : 500 cycles
System connector : 10,000 cycles
Flips/Hinges : 1,000 cycles
RF connector : 5,000

1/52 41-FEA 202 8370

Free Fall Test

1m drop height on to concrete
- all sides
- all faces
- all corners
- any extended features

IEC 60068-2-32 Test Ed