F100 PI – PING
Use function F100 PI to ping a remote host to see if it is reachable. If no IP Address is provided, F100 PI
uses the XL-GPS’s own IP Address, and tests whether the XL-GPS’s network port has a good network
connection.
To ping a known host, enter:
F100 PI<S><IP Address><CR>
For example:
F100 PI 206.254.000.021<CR>
The unit responds (example):
PING 206.254.000.021: REMOTE HOST FOUND.<CR><LF>
or
PING 206.254.000.021 : REMOTE HOST NOT FOUND.<CR><LF>
To test if the XL-GPS’s network port has a good connection, enter the following using in a serial port
session:
>f100 PI<CR>
XL-GPS responds:
PING : REMOTE HOST FOUND.<CR><LF>
or it responds:
PING : REMOTE HOST NOT FOUND.<CR><LF>
F100 PN – Change User Name
Use function F100 PN to change a user name. In a network port session, F100 PN changes the name of
the user you logged in as; operator or guest. In a serial port session, F100 PN changes the name of the
operator
user.
See “Command Line Interface” on page 29.
To change the user name, enter:
F100<S>PN<CR>