3. Interface

specifications

3.1 Parallel interface (Centronics)
1) Data input

: 8 bit parallel method(DATA 0 – DATA 7)

2) Control signals

: /ACK, BUSY, /STB, /ERROR, PE, SLCT, /INIT

3) Input signal to a printer

DATA 0 – 7

: 8 bit parallel signal(positive logic)

/STB

: Signal to read 8 bit data(negative logic)

/INIT

: Signal to reset an entire printer(negative logic)

/LF

: Signal to feed paper to print mechanism(negative logic)

4) Output signal from a printer

/ACK

: Enquiry signal for 8 bit data. It’s also pulse signal which is output after
BUSY signals (negative logic)

BUSY

: Indicate BUSY status of the printer. Inputs new data at LOW status
(positive logic)

/ERROR

: This signal becomes LOW when a printer is in the alarm status.

In the LOW status, all control circuits in the printer stops (negative logic)

PE

: Outputs when roll paper becomes empty (positive logic)

SLCT

: Signal to indicate on-line status (positive logic)

5) Input/Output signal level

Standard value

Code

Min. TYP. Max.

Unit

Input low level

V

IL

- -

0.18Vcc

V

Input high level

V

IH

0.7Vcc

-

-

V

Output low level

V

OL

- - 0.7Vcc

V

Output high level

V

OH

0.7Vcc

-

-

V

*I

OL

4mA


6) Input/Output conditions

VCC



10K


LF

IN PUT

VCC

VCC

74LV574

STROB

PD0~PD7

ACK, P E, SLCT, ERROR

BUSY

INIT IN

OUT PUT

OUT PUT

IN PUT

IN PUT

IN PUT

3.3K

100

470p

3.3k

3.3K

74LV14

74LV14

47

74LV32

47

1SS319

510

Advertising