Visca device setting command – Sony FCB-EX980S User Manual

Page 41

Advertising
background image

41

Command List

VISCA Device Setting
Command

Before starting control of the FCB camera, be sure to
send the Address command and the IF_Clear
command using the broadcast function.

For VISCA network administration

Address

Sets an address of a peripheral device. Use when
initializing the network, and receiving the following
network change message.

Network Change

Sent from the peripheral device to the controller
when a device is removed from or added to the
network. The address must be re-set when this
message is received.

Packet

Note

Address

88 30 01 FF

Always broadcasted.

Network Change

X0 38 FF

X = 9 to F: FCB camera address + 8

VISCA interface command

IF_Clear

Clears the command buffers in the FCB camera and
cancels the command currently being executed.

Command Packet Reply Packet

Note

IF_Clear

8X 01 00 01FF

X0 50 FF

IF_Clear (broadcast)

88 01 00 01 FF

88 01 00 01 FF

X = 1 to 7: FCB camera address (For inquiry packet)
X = 9 to F: FCB camera address +8 (For reply packet)

VISCA interface and inquiry

CAM_VersionInq

Returns information on the VISCA interface.

Inquiry

Inquiry Packet Reply Packet

Description

CAM_VersionInq 8X 09 00 02 FF Y0 50 GG GG HH HH JJ JJ KK FF GGGG = Vender ID

(0020: Sony)

HHHH = Model ID
042E: FCB-EX980S
042F: FCB-EX980SP
0430: FCB-EX980
0431: FCB-EX980P
JJJJ = ROM revision
KK = Maximum socket #(02)

X = 1 to 7: FCB camera address (For inquiry packet)
X = 9 to F: FCB camera address +8 (For reply packet)

Advertising