Self-diagnosis function, Specifications – Sony GDM-5510 User Manual

Page 19

Advertising
background image

19

EN

Self-diagnosis function

This monitor is equipped with a self-diagnosis function. If there is
a problem with your monitor or computer(s), the screen will go
blank and the ! (power) indicator will either light up green or
flash amber. If the ! (power) indicator is lit in amber, the
computer is in power saving mode. Try pressing any key on the
keyboard or moving the mouse.

x If the ! (power) indicator is green

1

Disconnect any plugs from the video input 1 and 2
connectors, or turn off the connected computer(s).

2

Press the ! (power) button twice to turn the monitor
off and then on.

3

Hold the control button upward for 2 seconds
before the monitor enters power saving mode.

If all four color bars appear (white, red, green, blue), the monitor
is working properly. Reconnect the video input cables and check
the condition of your computer(s).

If the color bars do not appear, there is a potential monitor failure.
Inform your service representative of the monitor’s condition.

x If the ! (power) indicator is flashing amber

Press the ! (power) button twice to turn the monitor off
and then on.
If the ! (power) indicator lights up green, the monitor is working
properly.

If the ! (power) indicator is still flashing, there is a potential
monitor failure. Count the number of seconds between amber
flashes of the ! (power) indicator and inform your service
representative of the monitor’s condition. Be sure to note the
model name and serial number of your monitor. Also note the
make and model of your computer and graphic board.

Specifications

CRT

0.24 mm aperture grille pitch
21 inches measured diagonally
90-degree deflection
FD Trinitron

Viewable image size

Approx. 403.8

× 302.2 mm (w/h)

(16

× 12 inches)

19.8" viewing image

Resolution

Maximum

Horizontal: 2048 dots
Vertical: 1536 lines

Recommended

Horizontal: 1600 dots
Vertical: 1200 lines

Input signal levels

Video signal

Analog RGB: 0.700 Vp-p
(positive), 75

SYNC signal

H/V separate or composite sync:
TTL 2.2 k

Ω, Polarity free

Sync on Green: 0.3 Vp-p
(negative)

Standard image area

Approx. 388

× 291 mm (w/h)

(15

3

/

8

× 11

1

/

2

inches)

or
Approx. 364

× 291 mm (w/h)

(14

3

/

8

× 11

1

/

2

inches)

Deflection frequency*

Horizontal: 30 to 130 kHz
Vertical: 48 to 170 Hz

AC input voltage/current 100 to 240 V, 50 – 60 Hz, 2.0 – 1.0 A
Power consumption

Approx. 135 W

Operating temperature

10 °C to 40 °C

Dimensions

Approx. 501

Ч 508 Ч 505 mm (w/h/

d) (19

3

/

4

Ч 20 Ч 20 inches)

Mass

Approx. 31.5 kg (69 lb 7 oz)

Plug and Play

DDC2B/DDC2Bi, GTF**

* Recommended horizontal and vertical timing condition

• Horizontal sync width duty should be more than 4.8% of

total horizontal time or 0.8 µs, whichever is larger.

• Horizontal blanking width should be more than 2.3 µsec.
• Vertical blanking width should be more than 450 µsec.

** If the input signal is Generalized Timing Formula (GTF)

compliant, the GTF feature of the monitor will automatically
provide an optimal image for the screen.

Design and specifications are subject to change without notice.