SUPER MICRO Computer MIIC-203 User Manual

Page 27

Advertising
background image

28

2. To Master Receive Data

On the main screen, use the I

2

C Destination Address list control to set the

slave address of the device you want to communicate with.

Main Application Screen

On the lower part of the main screen, set the Bytes to MasterRx edit box to
the number of bytes you want to read. For example: Set this to 1 to read a
single byte. Click on the Master RX button to receive the message. Data
received from the slave is displayed in the Received Messages text box on
the main screen. The Communications Events window should report “Master
RX Transfer Complete”. If this message does not appear, check the slave
device address, connections, and power.

If you get a “Slave Not Acknowledging” message in the Communications
Events window, this could mean you have the wrong address in the I

2

C

Destination Address, or the device is not answering to its address.

You have the option to Auto Repeat a transmitted message upon completion
by checking the Auto Repeat box. Also you may do a DoStop which will
perform repeated starts automatically. Another option you have is to do
“DoNak”, which allows you to Ack or Nak the last byte coming from a Slave
Transmitter. Some Slave Transmitter Devices require a Nak on the final byte
going across the bus. (Option only available for the windows iPort).

Advertising