SUPER MICRO Computer MIIC-203 User Manual

Page 49

Advertising
background image

50

Example Code

The following examples are written in MS Visual Basic V3 for Windows using the
serial communications control (MSCOMM.VBX). It can be used as a guide in
implementing iPort/AFM interface programs in other programming languages and
operating environments.

Note: This example code is available online at: http://www.mcc-us.com/202ug.htm#ExampleCode.

iPort/AFM Reset
Comm1.Output = Chr$(18)

'Ctrl/R

Comm1.Output = Chr$(18)

'Ctrl/R

Comm1.Output = Chr$(18)

'Ctrl/R

iPort/AFM Initialization
Comm1.Output = "/f0"

'Set iPort/AFM XON/XOFF Flow Control

Comm1.Output = Chr$(13)

Comm1.Output = "/i70"

'Set iPort/AFM’s Own Slave Address

Comm1.Output = Chr$(13)

Comm1.Output = "/d4e"

'Set Destination Slave Address

Comm1.Output = Chr$(13)

Comm1.Output = "/o"

'Open I

2

C Connection

Comm1.Output = Chr$(13)

Master Transmit Message
Comm1.Output = "/T~00~01"

'Send Master Tx Command

Comm1.Output = Chr$(13)

'Terminate Command

Master Receive Message
Comm1.Output = "/R10"

'Send Master Rx Command

Comm1.Output = Chr$(13)

'Terminate Command

Communication Event Processing
Static Sub Comm1_OnComm ()
Static LineBuf$

While Comm1.InBufferCount

Msg$ = Comm1.Input ' Get Comm input character
CharIn$ = Msg$