Chapter 2 Menu

• If you cannot execute an ADJUST or ANALYZE

menu operation when using the Sony BKM-14L
probe, try again after disconnecting and reconnecting
the probe.

• When using the Thoma TF6 probe, set the TF6

PRINT menu to off.

[B121]

SONY BKM-14L menu

Select the BKM-14L operation.
ADJUST... : Perform automatic color temperature

adjustment.

÷

[B1211]

ANALYZE: Display readout values on the screen.

÷

[B1212]

[B1211]

ADJUST menu

To start adjustment, proceed as follows.
When you use the previously adjusted values for
adjustment, you can make start adjustment by selecting
START without performing step (1) and step (2).
(1) Select either D65 or D93.

Rather than selecting D65 or D93, you may instead
enter the values of the CIE 1931 color system x
and y coordinates.

(2) Enter values for LOW LIGHT and HIGH LIGHT.
(3) Select START.

START: Start adjustment.

÷

[B12111]

X: Enter the x coordinate.
Y: Enter the y coordinate.
LOW LIGHT (20IRE): Enter the luminance (cd/m

2

)

for low light.

HIGH LIGHT (100IRE): Enter the luminance (cd/

m

2

) for high light.

D65: Use D65 setting.
D93: Use D93 setting.

[B12111]

START menu

The following message appears. Perform operation
according to the message to start adjustment.

SET PROBE ON CRT
PRESS ENTER

Adjustment starts when the probe is placed against the
center of the screen and the ENTER or Ent button is
pressed.

[B1212]

ANALYZE menu

The following message appears. Perform operation
according to the message to enable the BKM-14L to
read the color system and luminance value.

SET PROBE ON THIS CRT
PRESS ENTER

Attach the BKM-14L on the center of the CRT and
press the ENTER or Ent button.

÷

[B12121]

Once the BKM-14L has carried out calibration, the
BKM-14L can start analyze the monitor’s
performance.

[B12121]

SET PROBE ON THIS CRT menu

Display the color system and luminance readout values
from the BKM-14L system at the bottom of the CRT.
X: xxxx: Display the x coordinate of the color system.
Y: xxxx: Display the y coordinate of the color system.
L: xxxx: Display the luminance value.

[B122]

GRASEBY/MINOLTA/PHILIPS/THOMA

menu

The forth and lower levels of [B122] are the same as
those of the fifth and lower levels of [B1211]. Refer to
[B1211] and [B12111].

[B13]

COPY FROM menu

Select the source to be copied from.
OTHER VALUE... : Copy data from another channel

or from common data.

÷

[B131]

OTHER MONITOR... : Copy data from a BVM-

DxxE/DxxF series monitor.

÷

[B132]

MEMORY CARD... : Copy data from a monitor

memory card.

÷

[B133]

[B131]

OTHER VALUE menu

Select STD, COL1,COL2, or CH SET.

÷

Copy is

carried out.
STD: Copy common data (factory setting: D65).
COL1: Copy common data (factory setting: D93).
COL2: Copy common data (factory setting: D56/

D65

1)

).

CH SET: Copy data from a particular channel (factory

setting: D65). Enter the number of the channel
from which the data will be copied.

D65: Copy the color temperature of D65.
D93: Copy the color temperature of D93.

[B132]

OTHER MONITOR menu

Specify the address number of the monitor.
MONITOR ADDRESS: Input the address number of

the monitor from which the data will be copied.

÷

[B1321]

1) D56: BVM-D20F1U/D24E1WU/D32E1WU

D65: BVM-D20F1E/D20F1A/D24E1WE/D24E1WA/D32E1WE/D32E1WA

........................................................................................................................................................................................................