Setting lists in the input configuration menu – Sony BVM-D20F1U User Manual

Page 43

Advertising
background image

37

Chapter 2 Menu

This section explains the setting lists displayed in the
menu.

How to read the setting lists

• For purposes of explanation, each setting list is

preceded by a menu number. These numbers are not
displayed on the screen.

For more information about the menu number, see “About
menu numbers” on page 23.

• The arrow mark (

÷) refers you to another setting list

that appears after you make the setting, or to an
operation that is carried out as a result of the setting.
When there is no arrow mark, the menu does not have
any sub-list.

[C1]

INPUT CONFIGURATION menu (1/2)

Set input signal data for each channel.
xxCH: Current channel is indicated. To change the

channel, enter a channel number with the numeric
keypad. The settings below will be stored as
information about the signal to be connected to this
channel.

FORMAT... : Select the input signal type.

÷[C11]

SLOT NO: Enter the slot number.
INPUT NO: Enter the input connector number.
YC SEP... : Select Y/C separation filter.

÷[C12]

SYNC MODE: Select the sync signal.

INT: Use an internal sync signal.
EXT: Use an external sync signal.

SCREEN MODE... : Select the scan size.

÷[C13]

SAFE AREA DISPLAY: Choose whether or not to

display the safe area (OFF or ON).

MODE... : Select the display mode for safe area.

÷[C14]

APERTURE: Choose whether to use aperture

adjustment or not (OFF or ON).

APERTURE VALUE: Enter the aperture adjustment

value (0 to 200).

[C1]

INPUT CONFIGURATION menu (2/2)

Set input signal data for each channel.
xxCH: Current channel is indicated. To change the

channel, enter a channel number with the numeric
keypad. The settings below will be stored as
information about the signal to be connected to this
channel.

FILTER... : Switch the filter operation (OFF or ON)

when the monochrome display is selected.

CHANNEL NAME... : Give the channel a name.

÷ [C15]

Setting Lists in the INPUT CONFIGURATION Menu

CONTROL: Use if either PRESET or CH SET

values are used for the CONTRAST/BRIGHT/
CHROMA/PHASE settings.
PRESET: Use values common to all channels.
CH SET: Use individual values for each channel.

COLOR TEMP...: Set the color temperature.

÷ [C16]

H PHASE: Set the horizontal picture position (–128 to

+127).

1125/60I SYSTEM: Select the number of active

scanning lines per frame. When the HD SDI signal
is input, the number of active scanning lines is
selected automatically.
1080I: The active scanning lines are 1080 lines
1035I: The active scanning lines are 1035 lines.

COPY FROM... : Select a method for copying data

from elsewhere.

÷[C17]

Note

For H PHASE data, if a value above or below the
allowable range is entered, the monitor will not
operate correctly.

[C11]

FORMAT menu

Select the signal format.
COMPOSITE... : Analog composite signal

÷ [C111]

YC... : Analog Y/C signal

÷ [C111]

COMPONENT... : Analog component or RGB signal
÷ [C112]
SDI... : Serial digital signal

÷ [C113]

Note

If there is no input connector or decoder corresponding
to a format, that format will not be selectable (the
cursor will skip over that item).

[C111]

COMPOSITE menu/YC menu

Select the format of a composite or Y/C signal.
NTSC: SETUP 7.5 or 0.
PAL: S (simple) or D (delay)
PAL-M: S (simple) or D (delay)
SECAM (for the COMPOSITE menu only)
AUTO: The format of the input signal is detected and

switched automatically.

1)

1) It will take a few seconds to detect the format of an input

signal when AUTO is selected. It is recommended that a
particular format be selected if it is determined.

(continued)

Advertising
This manual is related to the following products: