Djustments – Southbend 336D-3T User Manual

Page 28

Advertising
background image

A

DJUSTMENTS

M

ODEL

300 R

ESTAURANT

R

ANGES

P

AGE

28 O

PERATOR

S

M

ANUAL

1182298

REV

3

ADJUSTMENT

S

The bypass setting must be

calibrated before calibrating the

oven thermostat.

Allow the temperature to stabilize.

If the change is greater than 5

°

F

return to the bypass calibration.

Continued from Previous Page

Remove the oven knob and push
out the silver center from the rear
of the knob and reinstall the knob

on the thermostat.

Set the knob indicator to 400

°

F

and allow the oven to reheat.

NOTE! There are arrows around

the screw indicating (H) to increase

and (L) to decrease the

temperature.

Allow the temperature to stabilize.

Repeat this procedure until the

temperature stabilizes to +/-10

°

F

of the setting.

If the temperature cannot be set to

within +/-10

°

F replace the

thermostat and retest.

While holding the knob at the

400

°

F setting, push the screw in,

and turn it in the direction indicated

to calibrate the temperature.

NOTE! Only turn this screw by

small increments.

Scrape the paint seal off of the

screw.

To calibrate the temperature go to

the center of the thermostat.

The temperature should be within

+/- 10

°

F of the setting.

Reinstall the silver cover in

the knob center.

The temperature is stable when the

change is no more than 5

°

F.

Advertising