TROUBLESHOOTING

Refer to schematic P/N’s:

1181101 for 120V,

1181102 for 208/240V.

Continuity?

Reinstall the switch

cover and valve

panel.

Move the other wire to the lower

leg (N.O.) on the side of the switch.

Open the kick panel by raising it

and tilting the top outward.

If the blower runs,

the Door Switch is

wired wrong.

Open the oven door.

Turn on the power

switch.

Disconnect the main

power supply.

Check that one wire is connected

to the (common), 90

°

bottom

terminal of the switch.

Continues on following page.

Test oven.

Disconnect the main

power supply.

Check the facility's

power supplies.

Connect the main

power supply.

Reinstall the switch

cover and valve

panel.

Is the voltage

as specified?

Connect the main power supply.

Check the voltage specified by the Serial Plate

located behind the oven valve cover panel.

Move a DVM probe to the center terminal of the

switch wires 1 and 2.

No

Yes

Reinstall the switch cover and

valve panel.

Test blower.

Replace the switch.

CONVECTION OVEN BLOWER

DOES NOT RUN

Place switch in on position.

Place a DVM on the end terminals

of the blower switch wires 1 and 3.

Remove the protective cover from

over the switch.

Check that the wires and terminals

are secure on the switch.

REMOVE THE MAIN POWER

SOURCE. UNPLUG OR

DISCONNECT CIRCUIT

BREAKER.

Remove the control knobs from the

range.

CAUTION! WIRING BEHIND THE

PANEL OF THE NEXT STEP.

Remove the upper valve panel

cover screws and tilt the panel

forward to expose the back of

blower switch.

No

Yes