Roubleshooting – Southbend 336D-3T User Manual

Page 33

Advertising
background image

M

ODEL

300 R

ESTAURANT

R

ANGES

T

ROUBLESHOOTING

O

PERATOR

S

M

ANUAL

1182298

REV

3 P

AGE

33

TROUBLESHOOTING

Clockwise increases the pressure

and counter clockwise decreases

the pressure.

Be sure the capillary tubes are

away from burners, flames and

excessive heat.

Install the thermostat bulbs into

griddle tops.

Install the grates or griddle/hot

tops.

Reinstall the top valve cover panel

and knobs.

Each burner should have a steady

blue flame on each port of the

burner.

NOTE: Griddle and Hot Top

burners may be long and float

when cold. Allow the top to heat

before making burner adjustments.

Propane burners may have a slight

popping noise when turned off.

This is normal.

If the flame is long and yellow

adjust the burner shutter open.

Propane burners may have a small

amount of yellow tipping. This is

normal.

If the flame is rising up off of the

ports adjust the burner shutter

closed.

Test each burner.

Replace the pressure tap plug in

the manifold.

Re-light the pilots.

Continued from Previous Page

With the gas supply shut off to the

range install a pressure tap on the

manifold in the plugged tap

provided.

If the pressure is low remove the

cap from the pressure regulator on

the back of the range.

Shut off the range burners and

main gas and remove the pressure

tap.

Manifold pressures are:

Natural gas = 4" water column

Propane gas = 10" water column

Re-light the pilots and turn on all

the burners.

Observe the manifold pressure.

Install a manometer on the

pressure tap.

Turn on the gas supply to the

range.

Advertising