Reinstall the knobs, bezels and
valve cover panel.
NOTE! There are arrows around
the screw indicating (H) to increase
and (L) to decrease the
temperature.
Record the temperatures.
Recalibrate the thermostats.
Repeat this procedure at each
burner until the temperature
stabilizes to within 30
°
F of the set
temperature.
If the temperature cannot be set to
within 30
°
F replace the thermostat
and retest.
While holding the knob at the
300
°
F setting, push the screw in
and turn it in the direction indicated
to change the temperature.
NOTE! Only turn this screw by
small increments.
Scrape the paint seal off of the
screw.
To adjust the temperature, locate
the center of the thermostat.
NOTE: If the user is dissatisfied
with the griddle temperature
recovery time.
Place a digital surface temperature
instrument in the center of the
griddle.
Allow reading to stabilize to 300
°
F.
Remove the knobs, bezels and
valve cover panel.
Reinstall the silver cover in the
knob center.
Record this temperature.
Move the surface measurement
instrument to the center of the
griddle over each burner.
Continued from Previous Page
Average the temperature of each
burner reading.
Turn the bypass screw counter
clockwise to fully open the bypass
flame.