TROUBLESHOOTING RANGE TOP BURNERS

Consult the following table and the flowchart that begins on the following page.

Problem

Look for -

All burners and pilots in unit will not turn on

– Main gas supply to unit is “OFF.”

All burners produce excessive carbon deposits

– Incorrect gas type supplied to unit.

– Incorrect supply pressure.

Only some burners in a unit produce excessive carbon

deposits

– Incorrect orifices.

– Primary air not adjusted properly.

Only some pilots produce excessive carbon deposits

– Pilot gas not adjusted properly.

– Incorrect pilot orifice.

Top burner (not oven) will not come on

– Manual valve for top burner in “OFF” position.

– Pilot out.

Top section pilot will not stay ignited

– Pilot gas not adjusted properly.
– Clogged orifice.

– Draft condition.

– Improper ventilation system.

– Air in gas line.