1 configure network manager, Host command set reference – Siemens SIMATIC TIWAY 1 User Manual

Page 136

Advertising
background image

HOST COMMAND SET REFERENCE

UNILINK HOST ADAPTER

5–51

USER MANUAL

5.6.1

Configure Network Manager — 30

The CONFIGURE NETWORK MANAGER command configures the network
parameters and enables the Network Manager for operation. This command
can only be issued once.

Command:

30 [(oo vvvv)]

Response:

30

Usage:

CONFIGURATION

Modes:

NM

Parameters:

oo

The option number ranging from 01 to 0E. Any options not
specified in the command string will assume the default values.
Options can be specified in any order, but may only occur once.

vvvv

The parameter value.

The following describes the options and their associated
parameter values.

Option–01 = This parameter defines the TIWAY I network communications

parameters for both Channel A and Channel B. The defaults for
this option depend on the host port protocol. If this option is not
specified, the Network Manager will assume that only Channel A
is available and its communications parameters will default to:

D the settings on Dipswitch 1 when using NITP and

D when using the BDLC protocol,

d Local Line media is 115.2K baud, half duplex,
asynchronous, and NRZI, and

d RS–232–C/RS–423–A media is 9600 baud, full
duplex, synchronous, and NRZ.