Protocol command description – Silex technology SDZ-330 User Manual

Page 25

Advertising
background image

Protocol Command Description

COLOR CCD CAMERA

User’s Manual

49

COLOR CCD CAMERA

User’s Manual

48

Byte1

Byte2

Byte3

Byte4 || Byte5

Byte6

Byte7

Byte8

Byte9

Byte10

Byte11

Function Execution Description.
Command Packet

STX

CAM ID

HOST ADDR

Command

Data3

Data4

Data5

Data6

ETX

CHECK SUM

Return Packet

STX

CAM ID

HOST ADDR

Response

Data3

Data4

Data5

Data6

ETX

CHECK SUM

Function Reset all data to factory default value.
Command Packet

A0h

CAM ID

HOST ADDR

000Fh

00h

00h

00h

00h

AFh

CHECK SUM

Return Packet

A0h

CAM ID

HOST ADDR

000Fh

00h

00h

00h

00h

AFh

CHECK SUM

Function

Move focus lens to far direction.

Command Packet

A0h

CAM ID

HOST ADDR

0100h

00h

00h

00h

00h

AFh

CHECK SUM

Return Packet

A0h

CAM ID

HOST ADDR

0100h

00h

00h

00h

00h

AFh

CHECK SUM

Function

Move focus lens to near direction.

Command Packet

A0h

CAM ID

HOST ADDR

0200h

00h

00h

00h

00h

AFh

CHECK SUM

Return Packet

A0h

CAM ID

HOST ADDR

0200h

00h

00h

00h

00h

AFh

CHECK SUM

Function

Move zoom lens to wide direction.

Command Packet

A0h

CAM ID

HOST ADDR

0040h

00h

00h

00h

00h

AFh

CHECK SUM

Return Packet

A0h

CAM ID

HOST ADDR

0040h

00h

00h

00h

00h

AFh

CHECK SUM

Function

Move wide lens to tele direction.

Command Packet

A0h

CAM ID

HOST ADDR

0020h

00h

00h

00h

00h

AFh

CHECK SUM

Return Packet

A0h

CAM ID

HOST ADDR

0020h

00h

00h

00h

00h

AFh

CHECK SUM

Function

Stop zoom & focus lens moving.

Command Packet

A0h

CAM ID

HOST ADDR

0000h

00h

00h

00h

00h

AFh

CHECK SUM

Return Packet

A0h

CAM ID

HOST ADDR

0000h

00h

00h

00h

00h

AFh

CHECK SUM

Function

Unconditionally execute auto focus.

Command Packet

A0h

CAM ID

HOST ADDR

0045h

00h

00h

00h

00h

AFh

CHECK SUM

Return Packet

A0h

CAM ID

HOST ADDR

0045h

00h

00h

00h

00h

AFh

CHECK SUM

Function

Move to ZOOM position that is set up by users

Command Packet

A0h

CAM ID

HOST ADDR

00FFh

P1

P2

P3

00h

AFh

CHECK SUM

Return Packet

A0h

CAM ID

HOST ADDR

00FFh

P1

P2

P3

00h

AFh

CHECK SUM

Parameter P1, P2 : ZOOM position set (0000h~06EAh)

P3 : D-ZOOM position set(00h~03h)

Function

Save current user preset configuration information.

Command Packet

A0h

CAM ID

HOST ADDR

0003h

P1

00h

00h

00h

AFh

CHECK SUM

Return Packet

A0h

CAM ID

HOST ADDR

0003h

P1

00h

00h

00h

AFh

CHECK SUM

Command Name

Reset

Focus Far

Focus Near

Zoom Wide

Zoom Tele

AF Stop

One push AF

ZOOM Direct

USER PRESET Save

Advertising