Removing and installing the lamp unit – Sharp PG-A10X User Manual

Page 62

Advertising
background image

-58

Lamp
unit

BQC-PGA10X//1

Removing and Installing
the Lamp Unit

Info

• Be sure to remove the lamp unit using the

handle. Be sure not to touch the glass sur-
face of the lamp unit or the inside of the
projector.

• To avoid injury to yourself and damage to

the lamp, be sure to carefully follow the
steps below.

• Do not loosen other screws except for the

filter/lamp unit cover and lamp unit.

• Please refer to the installation manual in-

cluded with the lamp unit.

1

Press

on the projector to

turn off the power.

• Wait until the cooling fan stops.

Warning!

• Do not remove the lamp unit from the

projector right after use. The lamp will
be very hot and may cause burn or in-
jury.

2

Disconnect the power cord.

• Unplug the power cord from the AC

socket.

• Leave the lamp until it has fully cooled

down (about 1 hour).

3

Change the air filter.

• Change the air filter whenever you in-

stall the lamp unit (see pages

53

and

54

).

4

Remove the filter/lamp unit
cover.

• Turn the projector over. Loosen the user

service screw (1) that secures the fil-
ter/lamp unit cover. Pressing the tab
(2), remove the filter/lamp unit cover
(3).

1

2

3

User
service
screw

Tab

AC socket

Regarding the Lamp

Power OFF button