In compliance with (em), Approved by, Mains unit – Sennheiser EvolutionWireless EW 300 Series User Manual

Page 35: In compliance with, Sk 300 and skm 300, Rf characteristics

Advertising
background image

Specifications

33

In compliance with (EM)

Approved by

In compliance with

Certified by cCSAus KL, 60065, CSA.

SK 300 and SKM 300

Europe:

USA:

EMC

EN 301489-1/-9

Radio

EN 300422-1/-2

Safety

EN 60065

47 CFR 15 subpart B

Canada:

Industry Canada

RSS 210,

IC: 2099A-G3SKMEM

Mains unit

Input voltage

100 to 240 V~, 50/60 Hz

Power/current consumption

max. 120 mA

Output voltage

12 V

Secondary output current

400 mA

Temperature range

–10°C to +40°C

Europe:

EMC

EN 55022, EN 55024,
EN 55014-1/-2

Safety

EN 60065

USA:

47 CFR 15 subpart B

Canada:

ICES 003

For accessories and information on connector assignment, visit the ew G3 product page at www.sennheiser.com.

RF characteristics

Modulation

wideband FM

Frequency ranges

516–558, 566–608, 626–668, 734–776,
780–822, 823–865 MHz (A to E, G, see page 4)

Transmission frequencies

1,680 frequencies, tuneable in steps of 25 kHz
20 frequency banks, each with up to 24 factory-preset
channels, intermodulation-free
6 frequency banks, each with up to 24 user programmable
channels

Switching bandwidth

42 MHz

Nominal/peak deviation

±24 kHz / ±48 kHz

Frequency stability

±15 ppm

RF output power at 50

Ω

typ. 10/30 mW, switchable

Pilot tone squelch

can be switched off