Overview of the displays of the em 300 receiver, B.ch: 20.24, Eq: + 12db p – Sennheiser EvolutionWireless EW 300 Series User Manual

Page 8

Advertising
background image

Product overview

6

Overview of the displays of the EM 300 receiver

After switch-on, the receiver displays the standard display “

Receiver Parameters

”. For further

illustrations and examples of the different standard displays, please refer to page 25.

This standard display displays the operating states of the receiver and provides the most
important information on the received transmitter – provided the linked transmitter
supports this function.

Display

Meaning

RF level “

RF

(Radio Frequency)

Audio level “

AF

(Audio Frequency)

Frequency bank and
channel

Current frequency bank and channel number

Frequency

Current receiving frequency

Name

Freely selectable name of the receiver

Pilot tone “

P

Activated pilot tone evaluation

Equalizer setting

Current equalizer setting

Output gain

Current output gain

Muting function “

MUTE

Receiver is muted

Receiver does not output an audio signal
(see also page 30).

Transmitter type

Product name of the linked ew G3 transmitter

The product name is displayed only if the linked
transmitter supports this function.

543.200

SKM300

ew300 G3

B.Ch: 20.24

PEAK

MUTE

EQ:

+ 12dB

P

-10

0

40
30
20
10

-20
-30
-40

AF

RF

MHz

ቧ ቨ ቩ

ቪ ቫ ቭ

ቢ ባ

Diversity display:

Antenna input I is active

Antenna input II is active

RF signal level:
Field strength of the transmitted signal

Squelch threshold level

40
30
20
10

RF

PEAK

-10

0

-20
-30
-40

AF

Modulation of the transmitter
with peak hold function.

When the level display for audio level shows full
deflection, the audio input level is excessively
high. When the transmitter is overmodulated
frequently or for extended periods of time, the

PEAK

” display is shown inverted.