Schumacher Manual Battery Charger SWI-1224 User Manual

Page 48

Advertising
background image

• 44 •

SPECIFICATIONS

18.

Data Plate

120V, 50/60Hz

230V, 50/60Hz

Single Phase Power Supply (Vac)

120

230

Frequency (Hz)

50/60

50/60

Charging Voltage(s) (V)

12/24

3

12/24

3

Starting Voltage(s) (V)

12/24

3

12/24

3

Effective Charging Current, Continuous (A)

15/30/60

1,4

15/30/60

1,4

Starting Current at 1.0 Volt (minimum) /Cell (A)

5

200/300

5,6

200/300

5,6

Max. Power Absorbed Charge/Start (KW)

1.43/8.0

1.43/8.0

Assembled Dimensions (cm)

80 x 40 x 29.2

80 x 40 x 29.2

Weight (Kg)

20

20

Circuit Breaker Protected Output

Yes

2

Yes

2

Circuit Breaker Rating (A)

120

120

Switched Output Current

1.

Automatic Reset Output Breaker

2.

Switched Output Voltage

3.

60A at 12V Setting only

4.

200A at 24V Setting, 300A at 12V Setting

5.

Duty Cycle limited to 3 seconds on, 240 seconds off