Appendix a troubleshooting, Troubleshooting chart, Ppendix – SMC Networks TigerStack 100 1000BASE-X User Manual

Page 163: Roubleshooting

Advertising
background image

A-1

A

PPENDIX

A

T

ROUBLESHOOTING

Troubleshooting Chart

Troubleshooting Chart

Symptom

Action

Cannot connect using

Telnet, Web browser,

or SNMP software

•

Be sure to have configured the agent with a valid IP
address, subnet mask and default gateway.

•

Check that you have a valid network connection to the
switch and that the port you are using has not been
disabled.

•

Check network cabling between the management station
and the switch.

•

If you cannot connect using Telnet, you may have
exceeded the maximum number of concurrent Telnet
sessions permitted. Try connecting again at a later time.

Cannot access the

on-board

configuration

program via a serial

port connection

•

Be sure to have set the terminal emulator program to
VT100 compatible, 8 data bits, 1 stop bit, no parity and
19200 bps.

•

If the switch is configured for Auto (baud rate detection),
the terminal emulator program must be set at
2400~19200 baud, 8 data bits, 1 stop bit, no parity, and
flow control set to none. Also, you must first press the
Enter key once to set the data rate and initialize the
connection.

•

Check that the null-modem serial cable conforms to the
pin-out connections provided in Appendix B.

Forgot or lost the

password

•

Contact SMC Technical Support for help.