Self-help guide – Keating Of Chicago Safe and Easy Filter User Manual

Page 8

Advertising
background image

Self-Help Guide

Motor runs but will not
pump oil.

Tub not set up properly.

Tub not connected to the motor
housing properly

Filter not connected inside of
cabinet

Valve not switched to “Oil to Fryer”

If there’s more than one fryer,
return valve not open.

Place components in tub per the following:

1. Sump screen on the very bottom
2. Filter paper over sump screen (Lie it flat

on the bottom, creasing the sides).

3. Hold down ring (ensure paper is not

folded, lock hold down ring into place
ensuring a tight seal).

4. Sprinkle acidox powder evenly over filter

paper (1bag per 40 lbs. of oil).

5. Crumb basket for large debris.

1. Remove tub from the filter cart

completely by pulling the release handle
located on the bottom of the filter control
panel.

2. Place the tub onto the filter cart by first

inserting the rear lip under the filter cart
frame and then laying down the front of
the tub flat onto the cart.

3. Connect the tub to the motor housing by

pulling together the handles on the tub
and the handles on the motor housing
(NOTE: Verify tight connection by pushing
back on the tub).

1. Ensure filter assembly is rolled straight

onto the rails inside of the cabinet.

2. Push filter assembly back as far as

possible

3. Ensure quick disconnect fitting on top of

filter connects automatically with quick
connect fitting inside of cabinet.

4. Pull on filter lightly to ensure a tight

connection

1. Set the black knob in the middle of the

filter control panel to the far right.

2. Try to filter again.

1. Open the door of the fryer you wish to

filter.

2. Pull the return valve handle (small black

knob) out as far as possible.

3. Attempt to filter again. When completed,

push the black knob in as far as possible
to close.

PROBLEM

PROBABLE

SOLUTION

CAUSE

(Follow Sequentially)

– 6 –

Advertising