Self-help guide (continued) – Keating Of Chicago Safe and Easy Filter User Manual

Page 9

Advertising
background image

Self-Help Guide (Continued)

Motor runs but will not
pump oil.

Motor not making any
noise

Oil not pumping through
the hose

Oil has not penetrated the filter
paper

Not plugged in

Motor has overheated

Valve not switched to “Oil to Hose”

1. Let oil sit in the filter pan for

approximately 2 minutes and try again

1. Plug filter into the receptacle inside of

cabinet

2. Turn ON/OFF switch to ‘ON’.

1. Allow motor to cool for approximately 10

minutes.

2. Press the reset button near the ON/OFF

switch on the filter control panel and try
again.

1. Set the black knob in the middle of the

filter control panel to the far left.

PROBLEM

PROBABLE

SOLUTION

CAUSE

(Follow Sequentially)

PREVENTIVE MAINTENANCE: Familiarize yourself with the proper filtering procedure prior to
attempting to filter

1.

To remove water, stir oil until bubbling stops; water will clog filter paper pores.

2.

Verify all connections, especially quick disconnects (under tub and inside fryer or CF cabinet) are
tight; not leaking oil or sucking air.

3.

Use only one sheet of filter paper properly sealed under hold down ring.

4.

Use a drain clean out rod if partial or full blockage in fryer drain is suspected.

5.

If filter was used for fryer boil out, run oil through filter to lubricate motor/pump.

6.

Clean filter and all components after each use. Do not permit oil to remain in filter drawer; it will clog
the pump.

7.

Verify all lights and controls operate.

8.

Adhere to operating instructions in sequence given for proper filtration.

9.

Prepare filter for next use by using new filter paper and Acidox Powder for each fryer.

– 7 –

Advertising