Calibration Utility for MICROSOFT WINDOWS

1–38

September 1997 Part No. 1H9659

4. Use the Linearity Reference Card to select a box number for each of

the six density ranges.

If all of the Visual Linearity numbers on the test print are box number 5,
the printer is already calibrated. You can close the Calibration Utility.

If the Visual Linearity numbers on the test print are not all box number 5,
you must recalibrate the printer. Go to step 5.

5. Click on the

Input button.

The Input Test Print Values dialog box opens.

6. Type in the values you select from the test print in the text boxes.

7. Click on the

Recompute the Table button.

The calibration table is computed using the specified values and the
Calibration Document window appears.

8. Click on the

Send button to send the table to the printer.