13. When turning the projector off, rotate the operating switch counter

clockwise one step. The lamp will go off, but the fan will continue

to operate. Allow the fan to operate for a few minutes to properly

cool the bulb, then shut off the fan by turning the operating switch

to the OFF position. Turn the power switch to the OFF position.

For added safety, your projector has a built-in fan/delay circuit. If

you turn the projector completely off without cooling the lamp, the

temperature probe will keep the fan running until the projector

cools down.

The flat mirror in the 560 Series is aluminum coated and works as a

surface reflecting mirror. In the 750 Series, there is a heat absorbing flat

mirror.

Take care not to leave finger prints, stains or scratches on the surface of

the elliptical mirror, the flat mirror or the Xenon bulb.

If the mirrors are smudged or stained, wipe them off gently with a lens

cleaner or a piece of gauze wetted with a mixture of alcohol and ether.

Connect the standard Kodak Ektgraphic-III Remote Control to the round,

5-pin remote control socket on the rear of the projector. This will allow

you to control forward/reverse and focus.

REMOTE-1 Connector (DIN 5P)

This connector is used with standard Kodak Ektagraphic

-

III

Remote

Controls.

1. Focus In

2. Slide Forward

3. Slide Reverse

4. Focus Out

5. COM

Cleaning the Mirrors &

Optical System

Remote Control

Operating the Unit & Remote Control

14

Flat Mirror

Xenon Bulb

Magnet Assembly

Elliptical Mirror

Housing

Insulation Plate

3

5

4

1

2