1. Remove two (2) screws on the side of the dissolve module and take

off the square cover on the dissolve module. Turn on the power

switches for the AVL/Dataton Dissolve Controller and the Navitar

Dissolve Interface unit.

2. Turn off the three set-up switches on your Navitar Dissolve Interface

unit. Rotate the variable resistor “C” to the position between the

cam and pin as it is shown in the diagram.

3. Turn on the three set-up switches on your Navitar Dissolve Interface

unit. Rotate the variable resistor “O” to adjust the relationship

between the cam and pin as shown in the diagram.

4. After the above adjustment, repeat the on/off action of the set-up

switch several times and check that the position in each time coin-

cides with the marking. Alternately repeat the adjustment of 2 and

3 until satisfactory results are achieved.