19

TK-860G/862G

Test Equipment Required for Alignment

Test Equipment

Major Specifications

1. Standard Signal Generator

Frequency Range

400 to 520MHz

(SSG)

Modulation

Frequency modulation and external modulation

Output

–127dBm/0.1

µ

V to greater than –7dBm/100mV

2. Power Meter

Input Impedance

50

Operation Frequency

400 to 520MHz or more

Measurement Capability

Vicinity of 100W

3. Deviation Meter

Frequency Range

400 to 520MHz

4. Digital Volt Meter

Measuring Range

1 to 20V DC

(DVM)

Accuracy

High input impedance for minimum circuit loading

5. Oscilloscope

DC through 30MHz

6. High Sensitivity

Frequency Range

10Hz to 1000MHz

Frequency Counter

Frequency Stability

0.2ppm or less

7. Ammeter

20A

8. AF Volt Meter

Frequency Range

50Hz to 10kHz

(AF VTVM)

Voltage Range

1mV to 3V

9. Audio Generator (AG)

Frequency Range

20Hz to 20kHz or more

Output

0 to 1V

10. Distortion Meter

Capability

3% or less at 1kHz

Input Level

50mV to 10Vrms

11. 4

Dummy Load

Approx. 4

, 10W or more

12. Regulated Power Supply

13.6V, approx. 20A (adjustable from 9 to 17V)
Useful if ammeter requipped

ADJUSTMENT

Lead wire +

MIC

Shield wire –

1

8

Tuning cable (E30-3383-05)

Adapter cable (E30-3383-05) is required for
injecting an audio if PC tuning is used.
See "PC Mode" section for the connection.

MIC connector
(Front view)

Test cable for microphone input (E30-3360-08)

1 : BLC
2 : PSB
3 : E
4 : PTT
5 : ME
6 : MIC
7 : HOOK
8 : CM

Advertising