Adjustment – Kenwood TK-862G User Manual

Page 25

Advertising
background image

25

ADJUSTMENT

Measurement

Test-

equipment

Unit

Terminal

Adjustment

Unit

Parts

Method

Specifications/Remarks

Condition

Item

TK-860G/862G

9. QT deviation 1) Set test mode

Power meter Rear

ANT

Front

CH /

0.75kHz

±

50Hz (Wide/Narrow)

• Wide

Select “FQT” in tuning mode. Deviation

panel

panel

“_.FQT”

meter

Deviation meter filter

Oscilloscope

LPF : 3kHz
HPF : OFF

AF VTVM

Front

MIC

PTT : ON

AG

panel

Adjust [***]

2) “_.F.Q.T”

PTT : ON
Adjust [***]

3) “_.F.Q.T._.

PTT : ON
Adjust [***]

• Narrow

4) “_FQT***.

0.35kHz

PTT : ON
Adjust [***]

10. DQT

1) Set test mode

Front

CH /

0.75kHz

±

50Hz (Wide/Narrow)

deviation

Select “FDQT” in tuning mode.

panel

• Wide

“F.DQT”
Deviation meter filter

LPF : 3kHz
HPF : OFF

PTT : ON
Adjust [***]

2) “F.D.Q.T”

PTT : ON
Adjust [***]

3) “F.D.Q.T._.

PTT : ON
Adjust [***]

• Narrow

4) “FDQT***.

0.35kHz

PTT : ON
Adjust [***]

11. DTMF

1) Set test mode

Front

CH /

3.0kHz

±

0.2kHz

deviation

Select “DTMF” in tuning mode.

panel

• Wide

Deviation meter filter

LPF : 15kHz
HPF : OFF

PTT : ON
Adjust [***]

• Narrow

2) “DTMF***.

1.5kHz

±

0.1kHz

PTT : ON
Adjust [***]

12. TONE

1) Set test mode

Front

CH /

3.0kHz

±

0.1kHz (Wide/Narrow)

deviation

Select “TONE” in tuning mode.

panel

• Wide

Deviation meter filter

LPF : 15kHz
HPF : OFF

PTT : ON
Adjust [***]

• Narrow

2) “TONE***.

1.5kHz

PTT : ON
Adjust [***]