Installation, Others, Fig. 6 ■ modifying the transceiver • horn alert – Kenwood TK-862G User Manual

Page 6: Fig. 4 kap-1 foil side view • public address, Fig. 5

Advertising
background image

6

TK-860G/862G

INSTALLATION

Others

If the PA and HR2 are not necessary and the speaker out-

put is output to an external unit through the KCT-19, connect
the KCT-19 C connector to CN8 on the TX-RX unit.

8C

R21

Q5

Q1

D2

Q6

Q1

Q6

4

IC9

Shift

register

IGN

±

+

±

+

KAP-1 (SWITCH UNIT : X41-3380-20)

W1

1

2

3

HOR

E

SB

W2

1

2

3

PA/LI

SPO

SPI

CN1

1

2

HR2

NC

CN2

1

2

3

HR1

E

SB

CN3

1

2

PAO/LIO

E

R1 0

C5 1000P

C6

1000P

C7

1000P

K2

D1

C3 0.01

C1

1000P

R3 0

R4 0

C2

1000P

D2

K1

C4 0.01

Q1

Q1 :

DTD114EK

D1,2 : 1SS193

CN3

CN7

13

+

R153

Audio
power amp

IC13

CN8

1

2

SP

E

Internal/External
speaker

TX-RX UNIT

B

BRN

ORG

YEL

C

C

GRN

GRN

KCT-19

13 10

1

3

6

12

15

KCT-19 Terminal

6 : Earth
10 : HR1
12 : PA (HR2)

Fig. 6

Modifying the Transceiver
• Horn alert

The signal from pin 4 of IC9 on the TX-RX unit turns Q5

and Q1 on and off and drives KAP-1 HA relay K2 to drive the
horn with a maximum of 2A.

The default output is HR1. The relay open output can be

obtained between HR1 and HR2 by removing R1 in the KAP-
1.

R1

Output form

HR1 (Default)

Enable

HR2

Disable

HR1

HR1

HR2

R1

TX-RX UNIT
(A/2)

ANT

KCT-19

CN2

Q19

R122

R153

Fig. 4

KAP-1 foil side view

• Public address

The signal from pin 13 of IC9 on the TX-RX unit drives PA

relay K1 in the KAP-1 and switches the audio power ampli-
fier output between the external PA system (through KCT-
19) and internal and external speakers.

To use the PA function, R153 on the TX-RX unit must be

removed.

R153

Use the PA function

Disable

Do not use the PA function

Enable

Fig. 5

Advertising
This manual is related to the following products: