ADJUSTMENT

Measurement

Test-

equipment

Unit

Terminal

Adjustment

Unit

Parts

Method

Specifications/Remarks

Condition

Item

24

TK-860G/862G

6. Modulation

1) Set test mode

Power meter Rear

ANT

Front

CH /

Make the de-

(Wide/Narrow)

balanced

MIC input : OFF

Deviation

panel

panel

modulation

• Wide

Select “BAL” in tuning mode. meter

waveform neat.

“_.BAL”

Oscilloscope

Deviation meter filter

LPF : 3kHz

AF VTVM

Front

MIC

HPF : OFF

AG

panel

De-emphasis : OFF

PTT : ON
Adjust [***]

2) “_.B.A.L”

PTT : ON
Adjust [***]

3) “_.B.A.L._.

PTT : ON
Adjust [***]

• Narrow

4) “_BAL***.

PTT : ON
Adjust [***]

7. Maximum

1) Set test mode

3.95kHz (Wide)

±

50Hz (Wide/Narrow)

deviation

Connect AG to the MIC

1.75kHz (Narrow)

• Wide

terminal.

(According to the

Select “MAX” in tuning mode.

larger +, –)

“_.MAX”
AG : 1kHz/50mV
Deviation meter filter

LPF : 15kHz
HPF : OFF
De-emphasis : OFF

PTT : ON
Adjust [***]

2) “_.M.A.X”

PTT : ON
Adjust [***]

3) “_.M.A.X._.

PTT : ON
Adjust [***]

• Narrow

4) “_MAX***.

PTT : ON
Adjust [***]

8. MIC

1) Set test mode

Check

±

3kHz

±

0.2kHz (Wide)

seisitivity

CH : CH1 - Sig1

±

1.5kHz

±

0.05kHz (Narrow)

check

AG : 1kHz/5mV
PTT : ON
Adjust [***]