Emergency mode, Installation – Kenwood TK-862G User Manual

Page 7

Advertising
background image

7

TK-860G/862G

INSTALLATION

F.RESET

R705

TX-RX unit B/2

Foil side

R142

TX-RX unit A/2

Foil side

Fig. 8

Emergency Mode

Transceiver Modification Procedure
• Install the foot switch

Install the foot switch through the KCT-19 and KCT-18.

When the switch is treaded on, the radio enters the emer-
gency mode.

• Change the power switch circuit

TX-RX unit (B/2) : Control section

$R705 : Attach (R92-1252-05, 0

)

TX-RX unit (A/2) : RF section

R142 : Remove (RK73GB1J473J, 47k

)

Once the transceiver is modified, it cannot be turned on

and off with the power switch. The power switch turns the
LCD backlight and display on and off. (The power is
switched on and off by IGNITION SENSE.)

IC502

CPU

6

Q506

87

88

25

20

$R705

Attach

0

Power
switch

MBL

MBL

SB

Q505

Key
backlight

LCD

IC510

1

3

CN5

R142

47K

Remove

IC14

KCT-19

15 pin

KCT-18

Foot

switch

Control section

TX-RX section

Outside

13

1

3

6

15

KCT-19 Terminal

3 : Ignition sense
6 : Earth
15 : Foot switch

Fig. 7