Set the recording level (recording level [db]), Specify the recording method (sampling setup), Specify the sample that will be recorded – KORG sampler User Manual

Page 55: Record the sample, Listen to the sample

Advertising
background image

47

Quick Star

t

Power on/off

Demo song

Playing

programs

Playing

combinations

Using

controllers

Arpeggiator

RPPR

Program

editing

Combination

editing

Sampling

Song

2 Press the Sampling tab to access the Sampling page.

3 Set the parameters so that the signal from the AUDIO

INPUT 1 jack will be sent to the L channel.

Make the following settings.
“Input”: Analog
Input 1 “Level”: 127, “Pan”: as desired, “BUS Select”:
L/R

3. Set the recording level

(Recording Level [dB])

1 Play your guitar at the volume that you will be

recording.

If the display indicates “ADC OVERLOAD !!” (AD
converter input overload), turn the rear panel [LEVEL]
knob toward MIN to adjust the level appropriately.

The best audio quality will be obtained at the highest
possible level that does not cause an overload; i.e., a
level that is slightly below the point where “ADC
OVERLOAD !!” is displayed.

2 Press the SAMPLING [REC] key.

Play your guitar, and the level meter will indicate the
volume at which the guitar will be sampled.

Press the ARPEGGIATOR [ON/OFF] key to turn it on,
play the keyboard to start the arpeggio, and play your
guitar while adjusting the final volume.

Adjust the recording level as necessary, using the
Recording Level” slider located at the right of the dis-
play.

The power-on default is –12 dB. With a setting of –12
dB, CLIP will not be displayed even if the program
drum pattern and the guitar are played at the maxi-
mum level.

If the balance between instruments is not to your lik-
ing, use the [LEVEL] knob or the performance editor
Amp Level” to adjust the balance.

3 When you have finished making adjustments, press

the SAMPLING [REC] key.

Press the ARPEGGIATOR [ON/OFF] key to turn off
the arpeggiator.

4. Specify the recording method

(Sampling Setup)

1 In the Sampling page, set the following Sampling

Setup parameters.

“Source BUS”: L/R
“Trigger”: Sampling START SW
“Metronome Precount”: 4
“Save to”: RAM
“Mode”: Stereo
“Sample Time”: as desired

With these settings, if you press the SAMPLING [REC]
key to enter recording-standby mode and then press
the SAMPLING [START/STOP] key, recording will
begin after a four-beat count.

5. Specify the sample that will be recorded

Make settings as described in “4. Make settings for the
sample that will be recorded” (

☞p.45).

If you omit making settings at this point and simply con-
tinue with the settings of p.45, the sample will be assigned
to the next higher key of the same program number.

6. Record the sample

1 Press the ARPEGGIATOR [ON/OFF] key to turn it

on.

2 Press the SAMPLING [REC] key to enter record-

ready mode.

When you press the SAMPLING [START/STOP] key, a
count-down will begin. Play the keyboard during the
count-down

.

After a four-beat count-down, recording will start.
Play your guitar. The arpeggiator will also start after
the count-down.

3 Press the SAMPLING [START/STOP] key to stop

recording.

Sampling will also end automatically when the speci-
fied “Sample Time” is reached.

4 Press the ARPEGGIATOR [ON/OFF] key to turn it

off.

7. Listen to the sample

Now you can listen to the sample that was recorded. (“6.
Listen to the sample and edit it”

☞p.46)

Advertising