Ages 14, As shown in figures 12 & 1, Ages 14 and 1 – Lennox International Inc. 505 User Manual

Page 14: Properly (see wiring diagram figures 12, Are provided in figures 12, Control wiring, Page 14

Advertising
background image

Page 14

EDA 01/06

Figure 12

Typical EDA/Condensing Unit Wiring Diagram

INDOOR

UNIT

B4

FAN

Blue

Yellow

Black

K1

1st, cut yellow
wire here.

Use Wirenuts

*OUTDOOR RELAY Ċ

NOT REQUIRED WITH SINGLE-

SPEED OUTDOOR FAN

EDA

Violet

Orange

OUTDOOR WIRING

(VSM APPLICATION

ONLY)

Purple

Black

Black

Purple

VALVE
ACTUATOR

Y

ellow

Y

ellow

2

2nd, rewire yellow
wire as shown

Red

7

5

1

3

5

RED (NOT REQUIRED FOR

APPLICATIONS WITHOUT LSOM)

YELLOW

BLUE (NOT REQUIRED FOR SINGLE STAGE)

BLACK

BROWN (NOT REQUIRED FOR

APPLICATIONS WITHOUT LSOM)

SignatureStat

t

THERMOSTAT

INDOOR

UNIT

OUTDOOR

UNIT

TWISTED PAIR

PURPLE

OUTDOOR

SENSOR

(46M98)

RED

YELLOW

BLUE

BLACK

BROWN

BLACK

PURPLE

BLACK

RED

BLACK

Control Wiring

SEE CONTROL WIRING BELOW
FOR THERMOSTAT WIRING

DSĊY1 JUMPER − MUST BE
REMOVED FOR HUMIDITROL
OPERATION

Y1ĊY2 JUMPER − ONLY
REMOVE IF 2−STAGE COOLING

Y1ĊY2 JUMPER − IN FOR
SINGLE− STAGE COOLING;
REMOVED FOR 2−STAGE
COOLING

RED

BLACK

PURPLE

EDA

UNIT

FAN RELAY (NOT REQUIRED
WITH SINGLE-SPEED
OUTDOOR FAN)