TROUBLESHOOTING & REPAIR

F-51

F-51

LN-9 Wire Feeder

FIGURE F.12 – METER PANEL ASSEMBLY SCREWS

MOUNTING SCREWS

METER

DIGITAL METER AND METER PC BOARD REMOVAL AND

REPLACEMENT

(continued)

METER PC BOARD REMOVAL
PROCEDURE

1. Remove input power to the LN-9 wire feeder.

2. Locate and remove the two screws on the top

left and right side of the meter panel assem-
bly. See Figure F.12.

FIGURE F.13 – METER REMOVAL (WITH SHORT LEADS)

3. Lift the right side cover assembly.

4. Carefully remove the meter enclosure panel.

Note the limited lead length. See Figure F.13.