TROUBLESHOOTING & REPAIR

F-10

F-10

LN-9 Wire Feeder

Observe Safety Guidelines

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
216-383-2531 or 1-800-833-9353.

PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

TRIGGER INTERLOCK

FUNCTION PROBLEMS

The wire feeds when the interlock
switch is in the "ON" position. No
welding or gun trigger activation.

1. Check to see if the reed switch

2CR is stuck closed.

1. Check the 2CR reed switch for

sticking and associated leads
(#529 and #628) for shorts.

2. The power PC board may be

faulty. Replace.

With the interlock switch in the
"ON" position, the wire feed stops
when the gun trigger is released.

1. Check leads #529 and #628 for

loose or faulty connections
between the 2CR reed switch
and the power PC board.

1. The 2CR reed switch may be

faulty. Check to see if it closes
when welding.

2.

Check the continuity (zero
ohms) of leads #529 and #628
from the 2CR reed switch to the
power PC board. Also check
continuity of leads #530 and
#522 from the power PC board
to the interlock switch. See the
Wiring Diagram.

3. Check the interlock switch for

proper operation.

4. The power PC board may be

faulty. Replace.