A.2.3 the scsi busy led, Tablea.6 led connector j6, A.3 subsystem and subsystem vendor id – LSI U160 User Manual

Page 76: Tablea.7 subsystem and subsystem vendor id, A.2.3, The scsi busy led, A-10, Subsystem and subsystem vendor id, Led connector j6

Advertising
background image

3.75 pc

10.25 pc

11.25 pc

38.25 pc

4.333 pc

48.583 pc

52.5 pc

34.5 pc

44.25 pc

A-10

Technical Specifications

A.2.3

The SCSI Busy LED

The SCSI Activity LED interface on the LSIU160 is a four-wire
arrangement that allows the user to connect an LED harness to the
board. The buffered GPIO0_FETCH line (maximum output low voltage
0.4 V and minimum output low current 16 mA) is pulled low to complete
the circuit when a harness with an LED is attached. The SCSI Busy LED
connector is J6. The signal definitions for the SCSI Busy LED connector
are provided in

Table A.6

.

A.3

Subsystem and Subsystem Vendor ID

The Subsystem ID and System Vendor ID for the LSIU160 are provided
in

Table A.7

. The ID numbers are contained within the EEPROM of the

LSIU160. During system initialization, the ID numbers are loaded into the
Subsystem Vendor ID and Subsystem ID registers of the LSIU160 SCSI
Controller (the LSI53C1010). For more information on the operation of
the Subsystem Vendor ID and Subsystem ID registers, refer to the
LSI53C1010 PCI to Dual Channel Ultra3 SCSI Multifunction Controller
Technical Manual
.

Table A.6

LED Connector J6

Signal Name

Pin

LED+

1

LED

2

NC

3

NC

4

Table A.7

Subsystem and Subsystem Vendor ID

Subsystem

ID Number

Subsystem Vendor ID

1000

Subsystem ID

1030

Advertising