3.1.2 Electrical Characteristics

The LSI21003 maximum power requirements, which include SCSI
TERMPWR, under normal operation are listed in

Table 3.1

:

The PCI

PRSNT1#

and

PRSNT2#

pins are set to indicate a 15 W maximum

configuration.

Under abnormal conditions, such as a short on SCSI TERMPWR,
+5 V current may be higher. At temperatures of at least 25

°

C, a current

of 3 A is sustained no longer than ten seconds before the self-resetting
TERMPWR short circuit protection device opens.

3.1.3 Thermal, Atmospheric Characteristics

The board is designed to operate in an environment, which is defined by
the following parameters:

Temperature range: 0 to 55

°

C (dry bulb)

Relative humidity range: 5% to 90% (noncondensing)

Maximum dew point temperature: 32

°

C

The board is designed for a storage and transit environment, which is
defined by the following parameters:

Temperature range:

45

°

C to +105

°

C (dry bulb)

Relative humidity range: 5% to 90% (noncondensing)

3.1.4 Electromagnetic Compliance

The board is designed and implemented so as to minimize
electromagnetic emissions, susceptibility, and the effects of electrostatic
discharge. The board carries the CE mark, C-Tick mark, FCC
Self Certification logo, Canadian Compliance Statement, and meets the
requirements of FCC and CISPR Class B.

Table 3.1

Maximum Power Requirements

+5 V DC

±

5%

1.5 A

Over the operating range 5

°

C to 55

°

C