LTRx-512 Installer’s Guide

8

Note: UL regulations require that you do NOT place high voltage (120V) and low
voltage communication cables in the same conduit or through the same knockout holes

Follow the wiring steps in the next chapter

For the cleanest installation, mount the display unit over a standard “double gang” 4-inch
electrical box

Route the other end of the 8-foot connection cable to this electrical box

Place two #8 screws, 12 inches apart and level, ½-inch down from the top of the electrical
box

Connect the 8-foot connection cable and any communication cables to the display unit

Check your connections, then turn your Master on using the On/Off switch on the power
supply board

Attach the furnished cover to the power supply using four 6-32 screws (two of these
screws you earlier removed from the display unit)