Lathem LTR-512 User Manual

Page 50

Advertising
background image

LTRx-512 Installer’s Guide

Wiring Diagrams

46

Fig. D7 – COMMUNICATION TERMINAL BLOCK

Rear of Display Unit


NOTES:
1. Twisted-pair (Cat-3/Cat-5) wire connects directly to Terminal Block; up to 2 wires per position
2. Pulse-sync input is same as provided in power supply. One (1) second (min.) dry-contact switch

closure across terminals causes Master to reset time to 12:00AM of nearest date

3. Grounds (GND) are “signal grounds”, not “chassis grounds”
4. Load on non-regulated 12VAC output must be less than 250mA
5. For DDC4R communications, the LTRx-512 automatically sets itself as a master or slave


Strain Relief for the Communications Cable

Using the two wire tie wraps included in the
installation kit, attach them to the terminal block
as shown in this sample to provide strain relief to
the communications cable. Use any two empty
positions.



Advertising