Lathem LTR-512 User Manual

Page 19

Advertising
background image

LTRx-512 Installer’s Guide

15

Auto Test the Bells

Use the Auto Bell Test feature to turn on all bell relays once per minute at the start of each
minute. Once you start this function, you can test the continuity of your bell wiring circuits. Use
the “hidden code” 2355878 [BELLTST] to start the Auto Bell Test. When you enter this code,
ignore anything that displays on the screen

Use Function [6] to disable any relays that you do not want to use in your testing

Once you finish testing, make sure you enter the hidden code again to stop the Auto Bell Test and
use Function [6] to enable any relays that you earlier disabled


Set Daylight Savings

Your Master comes set to adjust for daylight savings in the United States. If you live outside
the United States or if your region does not observe daylight savings, use Function [7] to
change the country code

Press

Display


[#]

SELECT FUNCTION CODE


[7]

ENTER COUNTRY CODE

FOR DAYLIGHT SAVINGS

TIME ADJUSTMENT:

08


[0]..[9]

Enter your country code from Appendix C


[#]

Press [#] to accept (or [*] to cancel)


If your region does not observe daylight savings, then set your country code to 00

Setup Communications (LTR8-512 and LTR8-512M only)

Use Function [B] if you use the LTR MasterLink or Terminal Manager software with your
Master. You can setup your LTR8-512 with LTR MasterLink using RS-232 (serial), RS-485
(networked) or Modem (remote) Communications

You must enter these same settings for your LTR8-512 in the Terminal Manager or
LTR MasterLink software