LTRx-512 Installer’s Guide

Wiring Diagrams

33

TYPE 15 -

STRAIGHT FREQUENCY


Clock correction and bell circuit operations are generated by sequentially applying various frequencies
onto the 120 VAC. Each bell and clock correction circuit has its own frequency. Each bell and clock
correction circuit has a receiver circuit that applies the associated bell or clock frequency (3510 Hz
normally used for clock signals). For daylight savings, the clocks advance to the proper time by normal
12-hour correction, not at 2:00 AM. The time sequence of applying the frequencies to the 120 VAC is
shown below, and the Master’s bell and system relays control these frequencies:

RELAY

FROM

TO


Bell Ckt. 1

H:MM:00

H:MM:05

Bell Ckt. 2

H:MM:05

H:MM:10

Bell Ckt. 3

H:MM:10

H:MM:15

Bell Ckt. 4

H:MM:15

H:MM:20

Bell Ckt. 5

H:MM:20

H:MM:25

Bell Ckt. 6

H:MM:25

H:MM:30


SK2

(Hourly Correction)

H:57:54

H:58:02

(12-Hour Correction) 5:57:54

5:58:08


SK1

(Hourly Correction &

12-HourCorrection)

H:57:00

H:59:00

(Bells)

35 sec of min

30 sec of

previous to

Bell time

Bell

NOTE: Bells must be programmed 1 minute ahead of desired time.

Bells will not work during manual clock corrections and at the 58

th

minute.


For Masters including firmware
versions prior to V2.17 only:
NOTE: The LTRx-512 was designed
to work with clocks that do not
require a generator pre-start to set the
frequency level. Clocks using this pre-
start may not work with the LTRx-
512 firmware older than V2.17.


All circuits should be fused or protected by a circuit breaker (10Amp maximum)

Bells should not be
scheduled for:
HH:58:SS
or
00:00:SS