Lennox Hearth ELITE EDVI25 User Manual

Page 10

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

10

Masonry Fireplace Installation Diagram

Vertical Term-
ination Cap
and Flashing.
Cat. No.
H0908

Liner Requirements:

Vertical Height Min. = 8 ft. (2.44 M)
Vertical height Max. = 40 ft. (12.2 M)

See Direct Vent System Components
on Page 9.

Exhaust and air
Intake collars

Hook up Air
& Exhaust
as Shown
Here

Air
Intake

Exhaust

Clay
Chimney
Liner

Damper plate is
removed or fastened
in open position

Masonry chimneys may take
various contours which the
fl exible liners will accomodate.
However, keep the fl exible liner
as STRAIGHT as possible, avoid
unnecessary bending.

Figure 14

Before running the fl exible liners, make sure that both liners will pass through
existing damper area. Remove or lock damper to allow the passage of the fl exible
liners. If the damper will not allow the passage of both liners, DO NOT PROCEED
FURTHER (the appliance may NOT be installed into the fi replace)

.

Factory Built Fireplace Installation Diagram

Vertical Termination Cap
and Flashing, Cat. No. H0908

Liner Requirements:

Vertical Height Min. = 8 ft. (2.44 M)
Vertical height Max. = 40 ft. (12.2 M)

Vertical Termination
Adapter

Storm Collar

Air
Intake

Exhaust

Exhaust and Air
Intake Collars

Hook up Air &
Exhaust as
Shown Here

Figure 15

Roof
Flashing

See Direct Vent System Components
on Page 9.

Use 3" diameter listed
liner (UL1181 or UL1777)
for the AIR INTAKE.

Use 3" diameter listed
liner (UL1777 ONLY) for
the EXHAUST

Use 3" diameter listed liner
(UL1181 or UL1777) for the AIR
INTAKE.

Use 3" diameter listed gas vent liner
(UL1777 ONLY) for the EXHAUST

The fl exible vent pipe must
NOT be allowed to sag behind
insert or in fi replace fl ue.

The fl exible vent pipe must
NOT be allowed to sag behind
insert or in fi replace fl ue.

Read fi replace

requirements,

page 4

Read Fireplace

Requirements on

page 4

• The Flex Kit, Cat. No. H0909 includes one 35' fl ex liner and four gear clamps.
• The Termination Kit, Cat. No. H0908 includes the termination cap with two
collinear collars for 3” fl ex attachments and fl ashing.

Make sure that both liners will pass through existing damper area. Remove or lock
damper to allow the passage of the fl exible liners. If the damper will not allow the
passage of both liners, DO NOT PROCEED FURTHER. Consult a local mason for
removal of the damper without risk of structural damage or leakage.

The standard cap in Termination Kit, H0908, is a
high wind cap

The standard cap
in Termination
Kit, H0908, is a
high wind cap

• The Flex Kit, Cat. No. H0909 includes one 35' fl ex liner and four gear clamps.
• The Termination Kit, Cat. No. H0908 includes the termination cap with two collinear
collars for 3” fl ex attachments and fl ashing.

Gear Clamps

Liner

Liner

Gear Clamps