Model no. edvi35, Model no. edvi30, Xxx xxx – Lennox Hearth ELITE EDVI25 User Manual

Page 17: Safety / listing labels - models: edvi30 & edvi35, Manufactured at: union city, tn, Serial number/nombre de serie

Advertising
background image

17

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

SAFETY / LISTING LABELS - MODELS: EDVI30 & EDVI35

MODEL NO.

EDVI35

MANUFACTURED AT:

Union City, TN

FOR USE WITH NATURAL GAS. EQUIPE POUR GAZ NATUREL

ALTITUDE


MIN. GAS SUPPLY PRESS (“WC)
PRESS MIN. D’ALIMENTATION (“ CE)
MANIFOLD PRESSURE (“WC)
PRESSION CE TUBULURE (“CE)
MANUFACTURER’S RECOMMENDED ORIFICE SIZE
DIMENSION DE L’INJECTEUR RECOMMANDE PAR
MANUFACTURIER (DMS)
MAX INPUT (BTU/HR)
ENTREE MAX
MIN INPUT (BTU/HR)
ENTREE MIN

0-4500 FT/PI

(0-1370M)

4.5”

3.5”

#33


35,000

25,500

ELECTRICAL RATING/EXI GENCES ELECTRIQUES:

-UNIT/APPAREIL: MILIVOLT
1 ph
60 HZ
120 VOLTS
LESS THAN 5 AMPS

MINIMUM

SIDEWALL

FLOOR

8”
0”

CLEARANCES TO

CEILING (FROM BOTTOM OF UNIT)

64”

COMBUSTIBLE

MATERIAL

MANTEL FROM TOP OF UNIT

18”

M ANTEL

DEPTH

DEGAGEMENT MUR

ADJACENTS

PLANCHER

0mm

MINIMUM DE

PLAFOND (DU BAS DE L’APPAREIL)

1626mm

MATERIAUX

COMBUSTIBLES

MANTEAU

457mm

PROFONDEUR DU MANTEAU

VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL. FOR INSTALLATION

IN SOLID FUEL FIREPLACES. THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE

WITH AIR FILTERS.

FOYER AU GAZ CHAUFFANT AVEC EVACUATION - NE DOIT PAS ETRE UTILISE AVEC UN

COMBUSTIBLE SOLIDE. DOIT ETRE INSTALLE DANS UNE CHEMINEE EXISTANTE QUI

BRULE LE COMBUSTIBLE SOLIDE. NE PAS UTILISER DE FILTRE A AIR AVEC CE FOYER AU

GAZ A EVACUATION.

FOR USE WITH GLASS DOOR CERTIFIED WITH THE APPLIANCE ONLY.

N’UTILISER SEULEMENT QUE LA PORTE DE VERRE CERTIFIE AVEC L’ APPAREIL.

“CAUTION:

Do not operate the appliance with glass removed, cracked or broken.

Replacement of panel should be done by a licensed or qualified service person.”

“This appliance is equipped at the factory for use with natural gas only. Units using

propane must be field converted using t he LP conversion kit,

FINAL INSPECTION BY:

ANSI Z21.88-2002

CSA 2.33-2002

CAN/CGA 2.17-M91

VENTED GAS FIREPLACE HEATER

FOYERA AU GAZ CHAUFFANT AVEC EVACUATION

P/N 9-1467B

SERIAL NUMBER/NOMBRE DE SERIE

XXX XXX

IIIIIIIIIIIIIIIIIIII

XXX

P/N 9-1467B

DU DESSUS DE L'APPAREIL

12”

203mm

305mm

Cat. No. H0921.

(MAX)

(MAX)

MODEL NO.

EDVI30

MANUFACTURED AT:

Union City, TN

FOR USE WITH NATURAL GAS. EQUIPE POUR GAZ NATUREL

ALTITUDE


MIN. GAS SUPPLY PRESS (“WC)
PRESS MIN. D’ALIMENTATION (“ CE)
MANIFOLD PRESSURE (“WC)
PRESSION CE TUBULURE (“CE)
MANUFACTURER’S RECOMMENDED ORIFICE SIZE
DIMENSION DE L’INJECTEUR RECOMMANDE PAR
MANUFACTURIER (DMS)
MAX INPUT (BTU/HR)
ENTREE MAX
MIN INPUT (BTU/HR)
ENTREE MIN

0-4500 FT/PI

(0-1370M)

4.5”

3.5”

#37


30,000

21,500

ELECTRICAL RATING/EXI GENCES ELECTRIQUES:

-UNIT/APPAREIL: MILIVOLT
1 ph
60 HZ
120 VOLTS
LESS THAN 5 AMPS

MINIMUM

SIDEWALL

FLOOR

8”
0”

CLEARANCES TO

CEILING (FROM BOTTOM OF UNIT)

64”

COMBUSTIBLE

MATERIAL

MANTEL FROM TOP OF UNIT

18”

M ANTEL

(MAX)

12”

DEGAGEMENT MUR

ADJACENTS

PLANCHER

203mm

0mm

MINIMUM DE

PLAFOND (DU BAS DE L’APPAREIL)

1626mm

MATERIAUX

COMBUSTIBLES

457mm

PROFONDEUR DU MANTEAU

305mm

VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL. FOR INSTALLATION

IN SOLID FUEL FIREPLACES. THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE

WITH AIR FILTERS.

FOYER AU GAZ CHAUFFANT AVEC EVACUATION - NE DOIT PAS ETRE UTILISE AVEC UN

COMBUSTIBLE SOLIDE. DOIT ETRE INSTALLE DANS UNE CHEMINEE EXISTANTE QUI

BRULE LE COMBUSTIBLE SOLIDE. NE PAS UTILISER DE FILTRE A AIR AVEC CE FOYER AU

GAZ A EVACUATION.

FOR USE WITH GLASS DOOR CERTIFIED WITH THE APPLIANCE ONLY.

N’UTILISER SEULEMENT QUE LA PORTE DE VERRE CERTIFIE AVEC L’ APPAREIL.

“CAUTION:

Do not operate the appliance with glass removed, cracked or broken.

Replacement of panel should be done by a licensed or qualified service person.”

“This appliance is equipped at the factory for use with natural gas only. Units using

propane must be field converted using the LP conversion kit, Cat. No. H0920.

FINAL INSPECTION BY:

ANSI Z21.88-2002

CSA 2.33-2002

CAN/CGA 2.17-M91

VENTED GAS FIREPLACE HEATER

FOYERA AU GAZ CHAUFFANT AVEC EVACUATION

P/N 9-1467A

SERIAL NUMBER/NOMBRE DE SERIE

XXX XXX

IIIIIIIIIIIIIIIIIIII

XXX

P/N 9-1467A

MANTEAU DU DESSUS DE L'APPAREIL

DEPTH

(MAX)

Advertising