Lennox Hearth ELITE EDVI25 User Manual

Page 7

Advertising
background image

7

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Top of Insert

(see "C" on Fig. 3)

2

3

4

5

6

7

8

9

10

11

12

0

0

18"

17"

16"

15"

1

\

14"

D

C

Figure 3

Figure 4a

Table 5

MINIMUM CLEARANCES TO COMBUSTIBLES: EDVI25, EDVI30 & EDVI35

These appliances can be installed in most residential
fi replace confi gurations. If installed close to an adjacent
wall, ensure that the minimum clearances to combustible
surfaces are maintained. A local building inspector should
review your plans prior to installation.

Refer to Figures 3, 4a, 4b and 5 for Clearances to Combus-
tibles.

Minimum clearances include spacers/standoffs or

surfaces to combustible construction.

Notes for Table 5:
*

This includes any projections such as shelves, window
sills, mantels, spacers/standoffs or surfaces to com-
bustible construction etc. above the appliance. Paint or
lacquer used to fi nish the mantel must be heat resis-
tant in order to avoid discoloration.

** If hearth is elevated, subtract 1 inch of hearth

extension required for every 2 inches of height (see
Figure 6).

Mantel

Ceiling (or)
Alcove Height

Side
Wall

Clearances to Combustibles

Inches (millimeters)

Min.

Min.

Min.

Min.

Min.

Min.

Min.

MAX.

MAX.

Min.

Max.

See Fig. 3 & 4a

0" (0 mm)

0" (0 mm)

**16" (406 mm)

**16" (406 mm)

49" (1245 mm)

48" (1219 mm)

50" (1270 mm)

49" (1245 mm)

36" (914 mm)

36" (914 mm)

8" (203 mm)

8" (203 mm)

64" (1626 mm)

64" (1626 mm)
See Fig. 3 & 4a

See Fig. 4a

See Fig. 4a

0" (0 mm)

**16" (406 mm)

44" (1118 mm)

45" (1143 mm)

36" (914 mm)

8" (203 mm)

64" (1626 mm)

See Fig. 3 & 4b

See Fig. 4b

A Side Wall
B
Ceiling or Alcove Height
C
* Mantel Height
D* Mantel Projection from Wall
E

Clearance to Floor

F** Hearth Protection

G

H Alcove Width

Alcove Depth

(from Fireplace Face)

EDVI30

EDVI35

EDVI25

Hearth Protection Width

I

A

G

E

C

B

Hearth Protection

Side View

Top of Insert

Mantel Clearance, Models: EDVI30 &
EDVI35:
The mantel should be located
in the shaded area (light gray) shown
below.

Existing Fireplace Hearth

F

15"

14"

2"

4"

6"

7"

At 7" hearth height, no hearth extension is required

16"

Figure 6

Side View
of Insert

Hearth Protection: For every 2" of hearth height,
subtract 1" of hearth extension required.

Top View Alcove

Hearth

H

Figure 5

Insert

Fireplace

I

Alcove Minimum Width: The specifi ed minimum width of the
alcove cannot be reduced with the use of wall protection.

Clearances

Top of Insert louver

(see "C" on Fig. 3)

0

0

8”

5”

1”

12”

15 1/2"

13"

11"

\

8 1/2"

D

C

Figure 4b

Side View

Mantel Clearance, Model: EDVI25: The
mantel should be located in the shaded
area (light gray) shown below.

13 1/2"

Advertising
This manual is related to the following products: